Specifications 3 section(s)

Click a section to see products, install method, warranty, and rooms specifying that material.
No CSI spec book in this bid package. Selected sections were not located in any uploaded specs PDF — this project ships drawings only. Refer to the reference sheets (cover sheet, general notes, finish schedule) for product callouts and install notes.
🟫
09 6500
RESILIENT FLOORING
Not found in spec book
🟥
09 6800
CARPETING
Not found in spec book
🟦
09 3000
TILING
Not found in spec book

Materials extracted from drawings (no spec book — pulled from notes)

Even without a CSI spec book, 195 product callouts and 51 code references were pulled from the cover/notes pages on the drawings themselves. = matches your trade scope (20 of 195 products are flooring-relevant). Verify against the source sheets before bidding.
CategoryProductModel / CodeSpec noteCode refSource
framingResilient ChannelRC channels at bottom of trusses for gypsum board attachment, fastened using sound isolation clipA-104
steel angleSteel Angle3" x 3" x 1" x 0.5"Gate stile reinforcementA-203
flooringCarpet and PadStop pad 2" before nosing to allow carpet to dip into nosingA-403
ceilingGypsum Board on Resilient Channels5/8" GYB CLG on resilient channelsA-404
flooringQuarry Tile FloorsQuarry tile floors with seal groutA-440
CeilingGYB-RC CeilingGypsum board resilient channel ceiling, continuous with exceptions for steel beams and load bearing wallsA-413
CeilingACT CeilingAcoustic ceiling tile systemA-413
flooringVinyl FloorEXG2-VF01Vinyl floor option for guestroomA-411
flooringTile FloorEXG2-T01Tile floor option for guestroomA-411
flooringCarpet FloorEXG2-CPT01 or EXG2-CPT02Carpet flooring options for guestroom accent wall areaA-411
flooring transitionsFloor TransitionEXG2-TR02, EXG2-TR03, EXG2-TR04Floor transitions for VF to carpet, tile to carpet, and tile to VFA-411
ceilingGypsum Board Ceiling5/8"On resilient channels with non-combustible insulationA-501
finish materialCultured StoneWith grouted joints on expanded mesh and membrane flashings at baseA-501
ceilingResilient ChannelsResilient channels for gypsum board ceiling supportA-505
copingCULTURED STONE COPINGWith grouted joints on expanded mesh and membrane flashingsA-503
drywallGYPSUM BOARD5/8" and 1/2"For ceiling on resilient channels and at shear wall locationsA-503
ceilingAcoustic Ceiling TileACT ceiling where indicatedA-502
ceiling systemGypsum Board Ceiling on Resilient Channels5/8"5/8" GYB ceiling on resilient channelsA-506
countertop edge trimSchiene · SchluterEdge trim for tile baseA-730
framingGypsum Board Ceiling5/8" GYB5/8" gypsum board ceiling on resilient channelsA-509
fastenersSimpson Fasteners · SimpsonPrescribed fasteners for strapping and structural connectionsA-000
Accessibility StandardsADA Standards for Accessible DesignFor Public Accommodations and Commercial Facilities: Title IIIADAA-102b
structural framing2x Continuous Bottom Plate (Treated)Treated lumber for first floor applicationsA-105
structural framing2x StudsPer structural drawingsA-105
sealantAcoustical SealantApplied each side of studs and at typical locationsA-105
insulationMineral Wool or Glass Fiber InsulationFit tightly between studsA-105
drywallType X Gypsum Board5/8 inchFire-rated, typical application on walls and ceilingsA-105
drywallGreen Board5/8 inchAt wet wall locationsA-105
drywallSound Board5/8 inchAcoustical application with Type X gypsum board overlayA-105
framingRC ChannelsSupports gypsum board at bottom of trusses and joistsA-105
flooringGypcrete3/4 inch minimum thickness with deck per structuralA-105
structural framingFloor TrussesPer structural drawingsA-105
structural framingFloor JoistsPer structural drawingsA-105
fireproofingDraftstoppingBetween all guest rooms and at ceiling spacesA-105
insulationNon-Combustible InsulationSolid fill all floor/ceiling, roof/ceiling, and ancillary spacesA-105
gypsum boardType X Gypsum Board5/8" Type X gypsum board, 2 layers each side of 2-hour walls continuous and uninterrupted from first floor slab to top of shaftUL Design U-301A-104
gypsum boardGreen Board5/8" green board as base layer for Type X gypsum board in guest room wallsUL Design U-311A-104
gypsum boardMoisture and Mold Resistant Gypsum BoardMoisture and mold resistant type in bathrooms, wet areas, and pool areaA-104
sound boardSound Board1/2" sound board base layer for gypsum board in 1-hour guest room wallsUL Design U-311A-104
framing2x Pressure Treated Bottom PlateTreated at first floorA-104
flooringGypcrete and Deck3/4" (minimum) gypcrete and deck per structuralA-104
fireproofingIntumescent Fireproofing PaintApplied to steel beams and columns in thicknesses required to provide 1-hour fire ratingA-104
doorsFire-Rated DoorsUL B Label, UL F/S LabelWood/hollow metal doors with UL labels for exit access openingsUL B Label, UL F/S LabelA-104
fire sprinkler systemSupervised Automatic Sprinkler SystemStandpipe system designed and installed as requiredNFPA 13A-104
fire alarm systemFire Alarm SystemDrawings to be submitted to franchise for approvalNFPA 14, NFPA 20A-104
gatePark Collection Madison Style Gates · CovritMadison StyleSlate Gray Deepwood PVC Panel and Frame Finish with steel pole hinges, glide rings, heavy duty handles, and drop pin locksA-202
pipeGalvanized Capped Pipe1 1/2"Set in concreteA-202
wallCMU Wall with Damp ProofingBelow grade level with reinforcing per structural, stucco coating to match buildingA-202
concreteConcrete Footing1'-6" DIA X 4'-0" DeepPer structural specificationsA-202
windowsEncore · Kawneer4 1/2" X 1 3/4" Framing SystemClear Anodized Aluminium Exterior, Interior and Sill Flashing. Low E Thermally Broken. U-Factor 0.50, SHGC 0.25A-308
windowsEmerge · QuakerE300 SeriesClear Anodized Aluminium Exterior, Interior and Sill Flashing. Low E Thermally Broken. U-Factor 0.50, SHGC 0.25A-308
windowsPTAC Unit Exterior GrilleTo meet Texas Department of Insurance requirements for impact resistance and design pressure ratingA-308
concrete finishlight broom finishReinforced concrete pool deck with light broom finishA-203
concrete admixture/coatingMORTEXContinuous application on reinforced concrete sidewalkA-203
handrailAluminum or Steel Handrail2" x 5.5"Sloped or half round top, factory painted finish or prefinished, color as approved by Hilton HotelsA-203
railing postAluminum or Steel Post1.5" square, 4" x 4" prefinishedSpaced at 6'-0" O.C., prefinished to match pool railA-203
railing picketsAluminum or Steel Pickets1.375" x 0.5"Spacing as required by local codesA-203
railing bottom railAluminum or Steel Bottom Rail1.5" squareContinuous horizontal memberA-203
gate hardwareSteel Spring Hinges · Stanley2-2060 Full MortiseFull mortise hinges for swimming pool gateA-203
gate postConcrete Post Hole12" diameterIn reinforced concrete pool deck, as manufactured by StanleyA-203
steel plateSteel Plate6" x 0.5"Base for gate post reinforcementA-203
Plumbing - Water ClosetsWater ClosetSeat height 17-19 inches, rough-in 12 inches, compliant with ADA standardsADA Standards for Accessible DesignA-102c
Plumbing - LavatoriesLavatoryCounter-mounted or wall-mounted, height 34 inches maximum, knee clearance requiredADA Standards for Accessible DesignA-102c
Plumbing - FaucetsFaucetLever-operated or automatic controls required, accessible height and reachADA Standards for Accessible DesignA-102c
Plumbing - Grab BarsGrab Bars1.25-1.5 inch diameter, 1.5 inches from wall, 250 lb load capacityADA Standards for Accessible DesignA-102c
windowsGL-10GL-10Fixed type window, Low E thermally broken, U-Factor 0.50 max, SHGC 0.25 maxTDI Impact Resistance, Design Pressure RatingA-313
windowsGL-10SGL-10SFixed type window, Low E thermally brokenTDI Impact Resistance, Design Pressure RatingA-313
windowsGL-10 (T)GL-10 (T)Tempered fixed type window, Low E thermally brokenTDI Impact Resistance, Design Pressure RatingA-313
windowsGL-10S (T)GL-10S (T)Tempered fixed type window, Low E thermally brokenTDI Impact Resistance, Design Pressure RatingA-313
doorsAUTO SLIDING DOORAutomatic sliding door, U-Factor 0.50 max, SHGC 0.25 maxTDI Impact Resistance, Design Pressure RatingA-313
materialsMTL PNLMetal panel infillA-313
materialsPainted GYBGypsum board, flush painted finishA-313
drywallType 'X' GWB5/8"Fire-rated gypsum wallboardA-403
stair nosingVinyl Stair Nosing1" nosing with 7" maximum rise, 11" typical treadA-403
lumber2x12 Wood Stringers(4) per stair run, do not over-cutA-403
lumber2x Wood TreadsFinish flooring over 2x wood treadsA-403
lumber12" Plywood RisersPlywood risers on stairsA-403
trimCorner GuardCut to 3/4" round trimA-403
trimRound Trim3/4" diameterContinuous 3/4-round, 1.5" diameterA-403
masonryCMU8"x16"x8"Concrete masonry unit per structuralA-403
roof systemPrefabricated Insulated Metal RoofInsulated metal roof system with membrane adhered to curbA-404
roofingRoof MembraneMembrane roofing adhered to curbA-404
roofingRoof InsulationRoof insulation systemA-404
ladderShips Ladder · Ladder IndustriesSL-10HD24" wide 65 degree angle fixed steel access ships ladder with safety grate steps, custom size to suit vertical rise to roofA-404
sealantNeoprene SealNeoprene seal for roof assemblyA-404
electricalFire Alarm Combination Horn/VisualFire alarm combination horn/visual deviceA-440
refrigerationRefrigeration EquipmentAll refrigeration must be capable of maintaining potentially hazardous foods at or below 41 degrees F. Stored frozen foods shall be maintainA-440
CeilingGYB-CLG CeilingGypsum board ceiling, continuous above ACT ceilings with exception for load bearing wallsA-413
Access PanelFire-Rated Access Panel12" x 12" FDWB12" x 12" fire-rated and insulated concealed frame access panel with wallboard beadA-413
LightingRecessed DownlightLED recessed downlight with GYB housing for rated floor/ceiling assembly penetrationA-413
LightingLED Strip LightingLinear under-cabinet light strip (optional)A-413
ElectricalGFCI ReceptacleGFCI duplex receptacle with integrated night light at bathroom locations; brand-approved devices per Design ConnectA-413
HardwareDoor StopFloor-mounted door stopA-413
HardwareDoor ViewerDoor viewer per door scheduleA-413
HardwareSwing Door GuardSwing door guardA-413
HardwareCaptive Key Card DeviceCaptive key card device, optional if required by codeA-413
HVACExhaust Grille12" x 12"12" x 12" fire-rated ceiling exhaust grilleA-413
HVACOutside Air GrilleOutside air grilleA-413
Fire SafetySmoke DetectorWall-mounted smoke detector and sprinkler head combinationA-413
Fire SafetyFire Alarm Horn/VisualFire alarm combination horn/visual strobe deviceA-413
HVACSprinkler HeadWall-mounted sprinkler head in guestroom, typicalA-413
ceilingGYB CLG CeilingGypsum board ceiling, continuous above ACT ceilings with exception for load bearing wallsA-411
lightingLED Strip LightingLinear Under-Cabinet Light StripOptional linear under-cabinet light stripA-411
electricalGFCI Receptacle with Integrated Night LightGFCI duplex receptacle with integrated night light; approved devices per Design ConnectA-411
baseBaseEXG2-B01, EXG2-B02, EXG2-B03, EXG2-B04Multiple base options for various floor and room typesA-411
wall coveringWallcovering or PaintEXG2-PT04, EXG2-PT05, EXG2-PT06, EXG2-WC01, EXG2-WC02, EXG2-WC03, EXG2-WC04Paint or wallcovering for main and accent walls; paint may be substituted where allowedA-411
window treatmentWindow Cornice and Roller ShadesEXG2-601Window cornice and roller shadesA-411
window sillWindow SillEXG2-SS01Window sill with front flush to wallA-411
doorsDoorEXG2-PL01 or EXP2-PL30Swing doors for guestroom and entryA-411
door framesDoor FrameEXG2-PT01 or EXP2-PT30Door frames for guestroom and entry doorsA-411
misc equipmentExhaust Grill12" X 12" Fire RatedFire-rated exhaust grillA-411
sheathingOSB/Plywood1/2"Weather barrier sheathingA-501
insulationFibrous InsulationWith continuous vapor barrierA-501
sealantSealantWith weeps at 4'-0" O.C.A-501
flashingStainless Steel Sill FlashingSet in full bed of sealantA-501
flashingStainless Steel Head FlashingSet in bed of sealant against air vapor barrier and window headA-501
flashingClear Anodized Aluminum Sill FlashingSet in bed of sealantA-501
exterior wall systemEIFS Exterior Wall System3.25" nominal and 1.75" nominalExterior Insulation and Finish SystemA-501
flooringGypcrete Topping1/2"Over structural flooringA-501
drywallGypsum Board5/8"Interior finish on wood stud walls and ceilingsA-501
insulationInsul-40Fill void at window openingsA-501
window treatmentRoller Shade and BracketAt guestroom windows onlyA-501
blockingWood BlockingAt window openings and jambsA-501
plywoodLaminate Faced Plywood Cover3/4"Removable top at guestroom windowsA-501
sill materialSolid Surface SillAt window sill locationsA-501
sealantSill SealerUnder bottom plateA-501
membraneWeather BarrierLap over foundation waterproofing; turn into openings with membrane flashingA-501
waterproofingFoundation WaterproofingConcrete floor/foundation with WP lap up to top of APC baseA-501
drywallGypsum Board (GYB)5/8"5/8" gypsum board for walls and ceilings, 2 layers at certain locationsA-505
flooringGypcrete ToppingGypcrete topping over structural flooringA-505
sheathingOSB/Plywood5/8"OSB or plywood sheathing at shear wall locationsA-505
insulationAcoustic Insulation5 1/2"5 1/2" acoustic insulationA-505
structuralWood Stud WallWood stud wall constructionA-505
structuralWood Floor Joists and Rim BoardsWood floor joists and rim boards per structural drawingsA-505
ceilingSuspended Acoustic or Gypsum Board CeilingSuspended acoustic or gypsum board ceiling per RCPA-505
exterior_wall_systemEIFS EXTERIOR WALL SYSTEMExterior insulation and finish systemA-503
roofingSPRAY POLYURETHANE ROOFING SYSTEMSPR roofing with flashing and cant stripA-503
flashingSTAINLESS STEEL SILL FLASHINGSSTSet in full bed of sealant at 4'-0" O.C. weepsA-503
fireproofingMINERAL FIBER FIRE PROOFING WRAPUL X311Applied to structural steel columns, 1-hour ratedUL X311A-503
blockingTREATED WOOD BLOCKINGFor flashing keeper support at roofA-503
roofing_aggregateSHEET METAL GRAVEL STOPAt roof edge with flashingA-503
framingWood Stud Wall6" and 4"Load-bearing and partition walls with 5/8" gypsum board, double studs at jambsA-502
exterior_wall_systemEIFS External Wall SystemPrimary exterior finish with drip groove and weather barrierA-502
flashingMembrane FlashingWeather barrier membrane flashing at openingsA-502
flooringGypcrete Topping3/4"Topping over structural flooringA-502
frameHollow Metal FrameExterior door frameA-502
frameAluminum FrameStorefront and door framingA-502
doorsADA Compliant Door ThresholdSet in full bed of perimeter sealantA-502
panelInsulated Aluminum Metal Panel1"Set into glazing pocket, color to match windowA-502
panelFormed Aluminum Metal Panel1/8"Column enclosure with sealant joints, color to match windowA-502
angleAluminum Angle5/8" X 5/8" X 1/8"Secured to window mullionA-502
fireproofingMineral Fiber Fire Proofing WrapApplied to structural steel column, 1-hour ratedUL X311A-502
foundationConcrete Floor/FoundationWith waterproofing up to floorA-502
insulationFoundation Insulation1"Foundation perimeter insulationA-502
sheathingTreated Plywood5/8"5/8" treated plywood at shear wall locationsA-506
framingFire Treated Wood Stud6"6" fire treated wood stud wall with 2 layers of 5/8" GYBA-506
framingWood Stud Wall4" and 6"6" and 4" wood stud wall with 5/8" GYBA-506
exterior finishSynthetic Stone SystemSynthetic stone system for exterior finishA-506
roofingSPR Roofing SystemSingle-ply roofing system with termination bar and sealantA-506
flashingSheet Metal FlashingSheet metal flashing, stop flashing, SPR flashing over roof parapetA-506
louverELF15J Thin Line Stationary Louver · RuskinELF15JClear anodized aluminum finish with stainless steel screw fasteners and clip brackets top, bottom, and midpoint connections with vertical miA-507
sunshadeRectangular Tube Blade Sunshade · RuskinSSRTHClear anodized aluminum finish with 6-inch rectangular tube blades, 10-inch rectangular tube fascia, and 10-inch flat bar outriggerA-507
insulationFoil Faced Mineral Fiber Window Spandrel Insulation1/4 inch foil faced mineral fiber for window spandrel insulationA-507
insulationFibrous Insulation with Continuous Vapor BarrierFibrous insulation with continuous vapor barrier for wall and floor cavitiesA-507
waterproofingWeather Barrier with Membrane FlashingWeather barrier, turn into opening over blocking with membrane flashingA-508
fire proofingMineral Fiber Fire Proofing Wrap1 hour ratedSprayed fire proofing of mineral fiber fire proofing wrap, 1 hour ratedUL X311A-508
structuralStructural Steel ColumnStructural steel column with sprayed mineral fiber fire proofingA-508
windowsInsulated Aluminum Metal Panel1" insulated1" insulated aluminum metal panel set into glazing pocket, color to match windowA-508
countertop materialPLAMCountertop with 2 layers 3/4" core materialA-730
sealantSilicone CaulkFor countertop sealingA-730
insulationPrefabricated Insulation Mech CurbMinimum 10" insulation thickness as indicated on plans; verify with mechanical supplierA-509
roofingRoofing SealantNeoprene SealerNeoprene sealer with gasketed fasteners at 18" o.c.A-509
roofingPrefabricated Membrane FlashingPrefabricated membrane flashing for roof vents and penetrationsA-509
roofingRoof Scupper20 OZ. Shop Soldered20 oz. shop soldered scupper set in 4" flange in full bed of mastic; fasten at 3" o.c., minimum 8" wideA-509
roofingPrefabricated Metal FlashingPrefinished metal flashing with cleat attachmentA-509
sealantBacker Rod and SealantBacker rod and sealant for joints and drip edgeA-509
glassWired Glass PanelMax. 100 sq.in. for 90 min. door panel type DP_N in 2 hour rated wallA-711
glassFirelite NT Glass45 min. rated glass for 1 hour rated DP_FG doors and sidelitesA-711
glassGL-1 Tempered or Laminated Safety GlassGL-1All glass in interior doors and sidelightsA-711
glassGL-10 Tempered or Laminated Safety GlassGL-10All glass in exterior doors and sidelightsA-711
doorsInsulated Hollow Metal DoorsExterior flush doors to be insulated hollow metalA-711
doorsAluminium Framed DoorsFGA doors with exterior GL-10 or interior GL-1 tempered or laminated safety glassA-711
hardwareArmor Plate1/2 inch stainless steel armor plate affixed to fire-rated doors, to be labeledA-711
hardwareKick Plate10 inch kick plate, 1/2 inch from edge of door leavesA-711
hardwareMagnetic Hold Open DeviceMagnetic hold open device at 6 inch heightA-711
door gasketNGP 5075B · National Guard ProductsNGP 5075BSmoke/Acoustical Gaskets - minimum triple-fin, self-adhering gasketingA-710
door gasket105 Cush N Seal · DHSI105 Cush N SealSmoke/Acoustical Gaskets - minimum triple-fin, self-adhering gasketingA-710
automatic sliding doorSL500 with ECODOOR seals · BESAMSL500Overhead concealed automatic sliding door with magnetic catchesA-710
sliding door trackSliding 200 series track · Pemko200 seriesTrack with wheel assembly, cushioned stops, bottom guide and fasciaA-710
sliding door hardwareBarn Door HardwareRLP black cast iron flat trackTop mount wheel assembly with cushioned stops and bottom guideA-710
door viewerDoor viewer160 degreeUL Listed glass lens with manufacturer-provided privacy capUL ListedA-710
door sweepLight-blocking neoprene door sweep1/2 inch1/2 inch neoprene door sweep for light blockingA-710
hingesHinges4-1/2 by 4-1/2 inchesQty 3 per leaf, power transfer type where notedA-710
lockset finishUS32D stainless steel finishUS32DSatin stainless steel 18-8 chromium-nickel, 300 Series, Austenitic, non-magneticA-710
lockset finishUS26D chromium plated finishUS26DSatin chromium platedA-710
Applicable codes (51)