| ★ | framing | Resilient Channel | | RC channels at bottom of trusses for gypsum board attachment, fastened using sound isolation clip | | A-104 |
| ★ | steel angle | Steel Angle | 3" x 3" x 1" x 0.5" | Gate stile reinforcement | | A-203 |
| ★ | flooring | Carpet and Pad | | Stop pad 2" before nosing to allow carpet to dip into nosing | | A-403 |
| ★ | ceiling | Gypsum Board on Resilient Channels | | 5/8" GYB CLG on resilient channels | | A-404 |
| ★ | flooring | Quarry Tile Floors | | Quarry tile floors with seal grout | | A-440 |
| ★ | Ceiling | GYB-RC Ceiling | | Gypsum board resilient channel ceiling, continuous with exceptions for steel beams and load bearing walls | | A-413 |
| ★ | Ceiling | ACT Ceiling | | Acoustic ceiling tile system | | A-413 |
| ★ | flooring | Vinyl Floor | EXG2-VF01 | Vinyl floor option for guestroom | | A-411 |
| ★ | flooring | Tile Floor | EXG2-T01 | Tile floor option for guestroom | | A-411 |
| ★ | flooring | Carpet Floor | EXG2-CPT01 or EXG2-CPT02 | Carpet flooring options for guestroom accent wall area | | A-411 |
| ★ | flooring transitions | Floor Transition | EXG2-TR02, EXG2-TR03, EXG2-TR04 | Floor transitions for VF to carpet, tile to carpet, and tile to VF | | A-411 |
| ★ | ceiling | Gypsum Board Ceiling | 5/8" | On resilient channels with non-combustible insulation | | A-501 |
| ★ | finish material | Cultured Stone | | With grouted joints on expanded mesh and membrane flashings at base | | A-501 |
| ★ | ceiling | Resilient Channels | | Resilient channels for gypsum board ceiling support | | A-505 |
| ★ | coping | CULTURED STONE COPING | | With grouted joints on expanded mesh and membrane flashings | | A-503 |
| ★ | drywall | GYPSUM BOARD | 5/8" and 1/2" | For ceiling on resilient channels and at shear wall locations | | A-503 |
| ★ | ceiling | Acoustic Ceiling Tile | | ACT ceiling where indicated | | A-502 |
| ★ | ceiling system | Gypsum Board Ceiling on Resilient Channels | 5/8" | 5/8" GYB ceiling on resilient channels | | A-506 |
| ★ | countertop edge trim | Schiene · Schluter | | Edge trim for tile base | | A-730 |
| ★ | framing | Gypsum Board Ceiling | 5/8" GYB | 5/8" gypsum board ceiling on resilient channels | | A-509 |
| fasteners | Simpson Fasteners · Simpson | | Prescribed fasteners for strapping and structural connections | | A-000 |
| Accessibility Standards | ADA Standards for Accessible Design | | For Public Accommodations and Commercial Facilities: Title III | ADA | A-102b |
| structural framing | 2x Continuous Bottom Plate (Treated) | | Treated lumber for first floor applications | | A-105 |
| structural framing | 2x Studs | | Per structural drawings | | A-105 |
| sealant | Acoustical Sealant | | Applied each side of studs and at typical locations | | A-105 |
| insulation | Mineral Wool or Glass Fiber Insulation | | Fit tightly between studs | | A-105 |
| drywall | Type X Gypsum Board | 5/8 inch | Fire-rated, typical application on walls and ceilings | | A-105 |
| drywall | Green Board | 5/8 inch | At wet wall locations | | A-105 |
| drywall | Sound Board | 5/8 inch | Acoustical application with Type X gypsum board overlay | | A-105 |
| framing | RC Channels | | Supports gypsum board at bottom of trusses and joists | | A-105 |
| flooring | Gypcrete | | 3/4 inch minimum thickness with deck per structural | | A-105 |
| structural framing | Floor Trusses | | Per structural drawings | | A-105 |
| structural framing | Floor Joists | | Per structural drawings | | A-105 |
| fireproofing | Draftstopping | | Between all guest rooms and at ceiling spaces | | A-105 |
| insulation | Non-Combustible Insulation | | Solid fill all floor/ceiling, roof/ceiling, and ancillary spaces | | A-105 |
| gypsum board | Type X Gypsum Board | | 5/8" Type X gypsum board, 2 layers each side of 2-hour walls continuous and uninterrupted from first floor slab to top of shaft | UL Design U-301 | A-104 |
| gypsum board | Green Board | | 5/8" green board as base layer for Type X gypsum board in guest room walls | UL Design U-311 | A-104 |
| gypsum board | Moisture and Mold Resistant Gypsum Board | | Moisture and mold resistant type in bathrooms, wet areas, and pool area | | A-104 |
| sound board | Sound Board | | 1/2" sound board base layer for gypsum board in 1-hour guest room walls | UL Design U-311 | A-104 |
| framing | 2x Pressure Treated Bottom Plate | | Treated at first floor | | A-104 |
| flooring | Gypcrete and Deck | | 3/4" (minimum) gypcrete and deck per structural | | A-104 |
| fireproofing | Intumescent Fireproofing Paint | | Applied to steel beams and columns in thicknesses required to provide 1-hour fire rating | | A-104 |
| doors | Fire-Rated Doors | UL B Label, UL F/S Label | Wood/hollow metal doors with UL labels for exit access openings | UL B Label, UL F/S Label | A-104 |
| fire sprinkler system | Supervised Automatic Sprinkler System | | Standpipe system designed and installed as required | NFPA 13 | A-104 |
| fire alarm system | Fire Alarm System | | Drawings to be submitted to franchise for approval | NFPA 14, NFPA 20 | A-104 |
| gate | Park Collection Madison Style Gates · Covrit | Madison Style | Slate Gray Deepwood PVC Panel and Frame Finish with steel pole hinges, glide rings, heavy duty handles, and drop pin locks | | A-202 |
| pipe | Galvanized Capped Pipe | 1 1/2" | Set in concrete | | A-202 |
| wall | CMU Wall with Damp Proofing | | Below grade level with reinforcing per structural, stucco coating to match building | | A-202 |
| concrete | Concrete Footing | 1'-6" DIA X 4'-0" Deep | Per structural specifications | | A-202 |
| windows | Encore · Kawneer | 4 1/2" X 1 3/4" Framing System | Clear Anodized Aluminium Exterior, Interior and Sill Flashing. Low E Thermally Broken. U-Factor 0.50, SHGC 0.25 | | A-308 |
| windows | Emerge · Quaker | E300 Series | Clear Anodized Aluminium Exterior, Interior and Sill Flashing. Low E Thermally Broken. U-Factor 0.50, SHGC 0.25 | | A-308 |
| windows | PTAC Unit Exterior Grille | | To meet Texas Department of Insurance requirements for impact resistance and design pressure rating | | A-308 |
| concrete finish | light broom finish | | Reinforced concrete pool deck with light broom finish | | A-203 |
| concrete admixture/coating | MORTEX | | Continuous application on reinforced concrete sidewalk | | A-203 |
| handrail | Aluminum or Steel Handrail | 2" x 5.5" | Sloped or half round top, factory painted finish or prefinished, color as approved by Hilton Hotels | | A-203 |
| railing post | Aluminum or Steel Post | 1.5" square, 4" x 4" prefinished | Spaced at 6'-0" O.C., prefinished to match pool rail | | A-203 |
| railing pickets | Aluminum or Steel Pickets | 1.375" x 0.5" | Spacing as required by local codes | | A-203 |
| railing bottom rail | Aluminum or Steel Bottom Rail | 1.5" square | Continuous horizontal member | | A-203 |
| gate hardware | Steel Spring Hinges · Stanley | 2-2060 Full Mortise | Full mortise hinges for swimming pool gate | | A-203 |
| gate post | Concrete Post Hole | 12" diameter | In reinforced concrete pool deck, as manufactured by Stanley | | A-203 |
| steel plate | Steel Plate | 6" x 0.5" | Base for gate post reinforcement | | A-203 |
| Plumbing - Water Closets | Water Closet | | Seat height 17-19 inches, rough-in 12 inches, compliant with ADA standards | ADA Standards for Accessible Design | A-102c |
| Plumbing - Lavatories | Lavatory | | Counter-mounted or wall-mounted, height 34 inches maximum, knee clearance required | ADA Standards for Accessible Design | A-102c |
| Plumbing - Faucets | Faucet | | Lever-operated or automatic controls required, accessible height and reach | ADA Standards for Accessible Design | A-102c |
| Plumbing - Grab Bars | Grab Bars | | 1.25-1.5 inch diameter, 1.5 inches from wall, 250 lb load capacity | ADA Standards for Accessible Design | A-102c |
| windows | GL-10 | GL-10 | Fixed type window, Low E thermally broken, U-Factor 0.50 max, SHGC 0.25 max | TDI Impact Resistance, Design Pressure Rating | A-313 |
| windows | GL-10S | GL-10S | Fixed type window, Low E thermally broken | TDI Impact Resistance, Design Pressure Rating | A-313 |
| windows | GL-10 (T) | GL-10 (T) | Tempered fixed type window, Low E thermally broken | TDI Impact Resistance, Design Pressure Rating | A-313 |
| windows | GL-10S (T) | GL-10S (T) | Tempered fixed type window, Low E thermally broken | TDI Impact Resistance, Design Pressure Rating | A-313 |
| doors | AUTO SLIDING DOOR | | Automatic sliding door, U-Factor 0.50 max, SHGC 0.25 max | TDI Impact Resistance, Design Pressure Rating | A-313 |
| materials | MTL PNL | | Metal panel infill | | A-313 |
| materials | Painted GYB | | Gypsum board, flush painted finish | | A-313 |
| drywall | Type 'X' GWB | 5/8" | Fire-rated gypsum wallboard | | A-403 |
| stair nosing | Vinyl Stair Nosing | | 1" nosing with 7" maximum rise, 11" typical tread | | A-403 |
| lumber | 2x12 Wood Stringers | | (4) per stair run, do not over-cut | | A-403 |
| lumber | 2x Wood Treads | | Finish flooring over 2x wood treads | | A-403 |
| lumber | 12" Plywood Risers | | Plywood risers on stairs | | A-403 |
| trim | Corner Guard | | Cut to 3/4" round trim | | A-403 |
| trim | Round Trim | 3/4" diameter | Continuous 3/4-round, 1.5" diameter | | A-403 |
| masonry | CMU | 8"x16"x8" | Concrete masonry unit per structural | | A-403 |
| roof system | Prefabricated Insulated Metal Roof | | Insulated metal roof system with membrane adhered to curb | | A-404 |
| roofing | Roof Membrane | | Membrane roofing adhered to curb | | A-404 |
| roofing | Roof Insulation | | Roof insulation system | | A-404 |
| ladder | Ships Ladder · Ladder Industries | SL-10HD | 24" wide 65 degree angle fixed steel access ships ladder with safety grate steps, custom size to suit vertical rise to roof | | A-404 |
| sealant | Neoprene Seal | | Neoprene seal for roof assembly | | A-404 |
| electrical | Fire Alarm Combination Horn/Visual | | Fire alarm combination horn/visual device | | A-440 |
| refrigeration | Refrigeration Equipment | | All refrigeration must be capable of maintaining potentially hazardous foods at or below 41 degrees F. Stored frozen foods shall be maintain | | A-440 |
| Ceiling | GYB-CLG Ceiling | | Gypsum board ceiling, continuous above ACT ceilings with exception for load bearing walls | | A-413 |
| Access Panel | Fire-Rated Access Panel | 12" x 12" FDWB | 12" x 12" fire-rated and insulated concealed frame access panel with wallboard bead | | A-413 |
| Lighting | Recessed Downlight | | LED recessed downlight with GYB housing for rated floor/ceiling assembly penetration | | A-413 |
| Lighting | LED Strip Lighting | | Linear under-cabinet light strip (optional) | | A-413 |
| Electrical | GFCI Receptacle | | GFCI duplex receptacle with integrated night light at bathroom locations; brand-approved devices per Design Connect | | A-413 |
| Hardware | Door Stop | | Floor-mounted door stop | | A-413 |
| Hardware | Door Viewer | | Door viewer per door schedule | | A-413 |
| Hardware | Swing Door Guard | | Swing door guard | | A-413 |
| Hardware | Captive Key Card Device | | Captive key card device, optional if required by code | | A-413 |
| HVAC | Exhaust Grille | 12" x 12" | 12" x 12" fire-rated ceiling exhaust grille | | A-413 |
| HVAC | Outside Air Grille | | Outside air grille | | A-413 |
| Fire Safety | Smoke Detector | | Wall-mounted smoke detector and sprinkler head combination | | A-413 |
| Fire Safety | Fire Alarm Horn/Visual | | Fire alarm combination horn/visual strobe device | | A-413 |
| HVAC | Sprinkler Head | | Wall-mounted sprinkler head in guestroom, typical | | A-413 |
| ceiling | GYB CLG Ceiling | | Gypsum board ceiling, continuous above ACT ceilings with exception for load bearing walls | | A-411 |
| lighting | LED Strip Lighting | Linear Under-Cabinet Light Strip | Optional linear under-cabinet light strip | | A-411 |
| electrical | GFCI Receptacle with Integrated Night Light | | GFCI duplex receptacle with integrated night light; approved devices per Design Connect | | A-411 |
| base | Base | EXG2-B01, EXG2-B02, EXG2-B03, EXG2-B04 | Multiple base options for various floor and room types | | A-411 |
| wall covering | Wallcovering or Paint | EXG2-PT04, EXG2-PT05, EXG2-PT06, EXG2-WC01, EXG2-WC02, EXG2-WC03, EXG2-WC04 | Paint or wallcovering for main and accent walls; paint may be substituted where allowed | | A-411 |
| window treatment | Window Cornice and Roller Shades | EXG2-601 | Window cornice and roller shades | | A-411 |
| window sill | Window Sill | EXG2-SS01 | Window sill with front flush to wall | | A-411 |
| doors | Door | EXG2-PL01 or EXP2-PL30 | Swing doors for guestroom and entry | | A-411 |
| door frames | Door Frame | EXG2-PT01 or EXP2-PT30 | Door frames for guestroom and entry doors | | A-411 |
| misc equipment | Exhaust Grill | 12" X 12" Fire Rated | Fire-rated exhaust grill | | A-411 |
| sheathing | OSB/Plywood | 1/2" | Weather barrier sheathing | | A-501 |
| insulation | Fibrous Insulation | | With continuous vapor barrier | | A-501 |
| sealant | Sealant | | With weeps at 4'-0" O.C. | | A-501 |
| flashing | Stainless Steel Sill Flashing | | Set in full bed of sealant | | A-501 |
| flashing | Stainless Steel Head Flashing | | Set in bed of sealant against air vapor barrier and window head | | A-501 |
| flashing | Clear Anodized Aluminum Sill Flashing | | Set in bed of sealant | | A-501 |
| exterior wall system | EIFS Exterior Wall System | 3.25" nominal and 1.75" nominal | Exterior Insulation and Finish System | | A-501 |
| flooring | Gypcrete Topping | 1/2" | Over structural flooring | | A-501 |
| drywall | Gypsum Board | 5/8" | Interior finish on wood stud walls and ceilings | | A-501 |
| insulation | Insul-40 | | Fill void at window openings | | A-501 |
| window treatment | Roller Shade and Bracket | | At guestroom windows only | | A-501 |
| blocking | Wood Blocking | | At window openings and jambs | | A-501 |
| plywood | Laminate Faced Plywood Cover | 3/4" | Removable top at guestroom windows | | A-501 |
| sill material | Solid Surface Sill | | At window sill locations | | A-501 |
| sealant | Sill Sealer | | Under bottom plate | | A-501 |
| membrane | Weather Barrier | | Lap over foundation waterproofing; turn into openings with membrane flashing | | A-501 |
| waterproofing | Foundation Waterproofing | | Concrete floor/foundation with WP lap up to top of APC base | | A-501 |
| drywall | Gypsum Board (GYB) | 5/8" | 5/8" gypsum board for walls and ceilings, 2 layers at certain locations | | A-505 |
| flooring | Gypcrete Topping | | Gypcrete topping over structural flooring | | A-505 |
| sheathing | OSB/Plywood | 5/8" | OSB or plywood sheathing at shear wall locations | | A-505 |
| insulation | Acoustic Insulation | 5 1/2" | 5 1/2" acoustic insulation | | A-505 |
| structural | Wood Stud Wall | | Wood stud wall construction | | A-505 |
| structural | Wood Floor Joists and Rim Boards | | Wood floor joists and rim boards per structural drawings | | A-505 |
| ceiling | Suspended Acoustic or Gypsum Board Ceiling | | Suspended acoustic or gypsum board ceiling per RCP | | A-505 |
| exterior_wall_system | EIFS EXTERIOR WALL SYSTEM | | Exterior insulation and finish system | | A-503 |
| roofing | SPRAY POLYURETHANE ROOFING SYSTEM | | SPR roofing with flashing and cant strip | | A-503 |
| flashing | STAINLESS STEEL SILL FLASHING | SST | Set in full bed of sealant at 4'-0" O.C. weeps | | A-503 |
| fireproofing | MINERAL FIBER FIRE PROOFING WRAP | UL X311 | Applied to structural steel columns, 1-hour rated | UL X311 | A-503 |
| blocking | TREATED WOOD BLOCKING | | For flashing keeper support at roof | | A-503 |
| roofing_aggregate | SHEET METAL GRAVEL STOP | | At roof edge with flashing | | A-503 |
| framing | Wood Stud Wall | 6" and 4" | Load-bearing and partition walls with 5/8" gypsum board, double studs at jambs | | A-502 |
| exterior_wall_system | EIFS External Wall System | | Primary exterior finish with drip groove and weather barrier | | A-502 |
| flashing | Membrane Flashing | | Weather barrier membrane flashing at openings | | A-502 |
| flooring | Gypcrete Topping | 3/4" | Topping over structural flooring | | A-502 |
| frame | Hollow Metal Frame | | Exterior door frame | | A-502 |
| frame | Aluminum Frame | | Storefront and door framing | | A-502 |
| doors | ADA Compliant Door Threshold | | Set in full bed of perimeter sealant | | A-502 |
| panel | Insulated Aluminum Metal Panel | 1" | Set into glazing pocket, color to match window | | A-502 |
| panel | Formed Aluminum Metal Panel | 1/8" | Column enclosure with sealant joints, color to match window | | A-502 |
| angle | Aluminum Angle | 5/8" X 5/8" X 1/8" | Secured to window mullion | | A-502 |
| fireproofing | Mineral Fiber Fire Proofing Wrap | | Applied to structural steel column, 1-hour rated | UL X311 | A-502 |
| foundation | Concrete Floor/Foundation | | With waterproofing up to floor | | A-502 |
| insulation | Foundation Insulation | 1" | Foundation perimeter insulation | | A-502 |
| sheathing | Treated Plywood | 5/8" | 5/8" treated plywood at shear wall locations | | A-506 |
| framing | Fire Treated Wood Stud | 6" | 6" fire treated wood stud wall with 2 layers of 5/8" GYB | | A-506 |
| framing | Wood Stud Wall | 4" and 6" | 6" and 4" wood stud wall with 5/8" GYB | | A-506 |
| exterior finish | Synthetic Stone System | | Synthetic stone system for exterior finish | | A-506 |
| roofing | SPR Roofing System | | Single-ply roofing system with termination bar and sealant | | A-506 |
| flashing | Sheet Metal Flashing | | Sheet metal flashing, stop flashing, SPR flashing over roof parapet | | A-506 |
| louver | ELF15J Thin Line Stationary Louver · Ruskin | ELF15J | Clear anodized aluminum finish with stainless steel screw fasteners and clip brackets top, bottom, and midpoint connections with vertical mi | | A-507 |
| sunshade | Rectangular Tube Blade Sunshade · Ruskin | SSRTH | Clear anodized aluminum finish with 6-inch rectangular tube blades, 10-inch rectangular tube fascia, and 10-inch flat bar outrigger | | A-507 |
| insulation | Foil Faced Mineral Fiber Window Spandrel Insulation | | 1/4 inch foil faced mineral fiber for window spandrel insulation | | A-507 |
| insulation | Fibrous Insulation with Continuous Vapor Barrier | | Fibrous insulation with continuous vapor barrier for wall and floor cavities | | A-507 |
| waterproofing | Weather Barrier with Membrane Flashing | | Weather barrier, turn into opening over blocking with membrane flashing | | A-508 |
| fire proofing | Mineral Fiber Fire Proofing Wrap | 1 hour rated | Sprayed fire proofing of mineral fiber fire proofing wrap, 1 hour rated | UL X311 | A-508 |
| structural | Structural Steel Column | | Structural steel column with sprayed mineral fiber fire proofing | | A-508 |
| windows | Insulated Aluminum Metal Panel | 1" insulated | 1" insulated aluminum metal panel set into glazing pocket, color to match window | | A-508 |
| countertop material | PLAM | | Countertop with 2 layers 3/4" core material | | A-730 |
| sealant | Silicone Caulk | | For countertop sealing | | A-730 |
| insulation | Prefabricated Insulation Mech Curb | | Minimum 10" insulation thickness as indicated on plans; verify with mechanical supplier | | A-509 |
| roofing | Roofing Sealant | Neoprene Sealer | Neoprene sealer with gasketed fasteners at 18" o.c. | | A-509 |
| roofing | Prefabricated Membrane Flashing | | Prefabricated membrane flashing for roof vents and penetrations | | A-509 |
| roofing | Roof Scupper | 20 OZ. Shop Soldered | 20 oz. shop soldered scupper set in 4" flange in full bed of mastic; fasten at 3" o.c., minimum 8" wide | | A-509 |
| roofing | Prefabricated Metal Flashing | | Prefinished metal flashing with cleat attachment | | A-509 |
| sealant | Backer Rod and Sealant | | Backer rod and sealant for joints and drip edge | | A-509 |
| glass | Wired Glass Panel | | Max. 100 sq.in. for 90 min. door panel type DP_N in 2 hour rated wall | | A-711 |
| glass | Firelite NT Glass | | 45 min. rated glass for 1 hour rated DP_FG doors and sidelites | | A-711 |
| glass | GL-1 Tempered or Laminated Safety Glass | GL-1 | All glass in interior doors and sidelights | | A-711 |
| glass | GL-10 Tempered or Laminated Safety Glass | GL-10 | All glass in exterior doors and sidelights | | A-711 |
| doors | Insulated Hollow Metal Doors | | Exterior flush doors to be insulated hollow metal | | A-711 |
| doors | Aluminium Framed Doors | | FGA doors with exterior GL-10 or interior GL-1 tempered or laminated safety glass | | A-711 |
| hardware | Armor Plate | | 1/2 inch stainless steel armor plate affixed to fire-rated doors, to be labeled | | A-711 |
| hardware | Kick Plate | | 10 inch kick plate, 1/2 inch from edge of door leaves | | A-711 |
| hardware | Magnetic Hold Open Device | | Magnetic hold open device at 6 inch height | | A-711 |
| door gasket | NGP 5075B · National Guard Products | NGP 5075B | Smoke/Acoustical Gaskets - minimum triple-fin, self-adhering gasketing | | A-710 |
| door gasket | 105 Cush N Seal · DHSI | 105 Cush N Seal | Smoke/Acoustical Gaskets - minimum triple-fin, self-adhering gasketing | | A-710 |
| automatic sliding door | SL500 with ECODOOR seals · BESAM | SL500 | Overhead concealed automatic sliding door with magnetic catches | | A-710 |
| sliding door track | Sliding 200 series track · Pemko | 200 series | Track with wheel assembly, cushioned stops, bottom guide and fascia | | A-710 |
| sliding door hardware | Barn Door Hardware | RLP black cast iron flat track | Top mount wheel assembly with cushioned stops and bottom guide | | A-710 |
| door viewer | Door viewer | 160 degree | UL Listed glass lens with manufacturer-provided privacy cap | UL Listed | A-710 |
| door sweep | Light-blocking neoprene door sweep | 1/2 inch | 1/2 inch neoprene door sweep for light blocking | | A-710 |
| hinges | Hinges | 4-1/2 by 4-1/2 inches | Qty 3 per leaf, power transfer type where noted | | A-710 |
| lockset finish | US32D stainless steel finish | US32D | Satin stainless steel 18-8 chromium-nickel, 300 Series, Austenitic, non-magnetic | | A-710 |
| lockset finish | US26D chromium plated finish | US26D | Satin chromium plated | | A-710 |